• Image One
Structural Design
Busan International Arts Center Design Competition
Address Busanjin-gu, Busan, Republic of Korea
Construction Year 2017.
Net Floor Area 19,860㎡
Story 3 Floors / 1 Floor
Building Type Public & Office Buildings
Structural System Reinforced Concrete
  Busan City held a design competition of a concert hall which specializes in music, represents the Southeast region and gives pride to Busan citizens. To provide not only high-quality performance services but also to support the optimal design plan that combines historicity, symbolism, creativity and artistry, We applied the importance factor as 1.0 according to the structural code. Reinforced concrete ramen structure, steel frame structure, steel truss structure are respectively applied at bottom level, ground level, long-span roof. Especially Camber was installed in steel truss structure to prevent the sag, ponding of snow, rain. Both isolated footings and mat foundations were applied for the foundation. The lateral force resistance system is a steel structure system that satisfies only the general rules of the steel structure standard.